Product Code:
Couldn't load pickup availability
ASKIN XFLAM is a patented Australian made material that is made from a syntactic phenolic foam that meets and exceeds all the performance requirements for rigid insulated material.
XFLAM Panel is a Group 1 material that meets the Factory Mutual requirements for internal, external, and roofing applications. XFLAM has achieved FM 4882 that certifies the insulated panels for smoke sensitive occupancies, perfect for food processing, cold storage, clean and pharmaceutical buildings.
Thermal Performance | ||||||
---|---|---|---|---|---|---|
Panel Thickness (mm) | U‑Value (W/m²K) at 23°C | R‑Value (m²K/W) at 23°C | R‑Value (m²K/W) at 15°C | R‑Value (m²K/W) at 0°C | R‑Value – Heat Flow Out (Winter) | R‑Value – Heat Flow In (Summer) |
50 | 0.71 | 1.40 | 1.40 | 1.50 | 1.70 | 1.60 |
75 | 0.45 | 2.05 | 2.10 | 2.20 | 2.30 | 2.20 |
100 | 0.34 | 2.75 | 2.80 | 2.95 | 3.00 | 2.90 |
125 | 0.29 | 3.45 | 3.50 | 3.70 | 3.80 | 3.60 |
150 | 0.24 | 4.15 | 4.25 | 4.45 | 4.50 | 4.30 |
175 | 0.21 | 4.85 | 4.95 | 5.20 | 5.20 | 4.90 |
200 | 0.18 | 5.55 | 5.65 | 5.95 | 5.90 | 5.60 |
250 | 0.14 | 6.90 | 7.05 | 7.40 | 7.30 | 7.00 |
Note: Total R‑Values calculated based on AS/NZS 4859.2:2018 and declared in accordance with AS/NZS 4859.1:2018. Compliant with the National Construction Code 2022.
Total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/ NZS 4859.2 2018. ASKIN XFLAM is manufactured, tested and packaged in conformance with AS/NZS 4859.1: 2018
Declared Product R-Value is calculated in accordance with AS/NZS 4859.1: 2018 as required for compliance to the National Construction Code 2022.
Features & Benefits
• Moisture resistant / 100% Recyclable
• Fire rated and FM Approved
• Resilient material for a changing climate
• Lengths available up to 22m
• Fast to install
• Thermally efficient (Product R-Values up to 6.9)
• Standard Warranty of 10 years
• Up to 120 minute FRL’s
• Suitable for temperature controlled environments
XFLAM Panels meet and exceed all the requirements of the National Construction Code with NATA approved testing and approvals. XFLAM Panel is a Factory Mutual (FM Approved) product meeting the rigorous international guidelines for fire compliance. XFLAM is a multi-layered product thus needs to satisfy the ISO AS9705 2003 Room test as stipulated in AS5637. ASKIN XFLAM meets a Group 1 system as a mechanically fixed install including concealed bracket. The panel has achieved a number of Fire Resistance Levels (FRL).
ASKIN Panel achieves the following ratings for panel tested in accordance with AS 1191-2002 and assessed against AS/NZS ISO 717.1:2004
Though predominantly installed vertically, ASKIN Performance Panels can also be installed horizontally or diagonally for aesthetic or practical reasons. Long panels or panels passing structural elements can be butt jointed with negative detail top hat sections. These can be supplied with fixing concealing caps. ASKIN Performance Panels can be fastened with a range of hardware available from ASKIN, including hidden fixings, Tek screws, mushroom head threaded rods, dome nut bolts, coach screws, suspension brackets and spring fixings. Please contact your ASKIN representative for more information.
*ASKIN recommend the use of clamps for ensuring minimum variable tolerance.
Colour Range
A full range of colours are available depending on Minimum Order Quantities and warranties.
Please contact your ASKIN representative as each project needs clarification on Solar Absorbance as stated in the NCC.
Environment
Resource Efficiency
As a low density insulation product XFLAM uses very little natural resources by volume to manufacture. This, coupled with the high insulation performance, mean that the energy savings from using XFLAM will amount to hundreds of times the energy required to produce the product.
Zero ODP
XFLAM foam insulation manufacturing does not use Ozone Depleting Substances such as CFCs, HCFCs or HFCs.
Haunches & Thermal Cuts
ASKIN has the ability to manufacture on-line haunches for wall to ceiling joints and thermal cuts for low temp rooms. The standard cuts range from 50mm to 225mm in multiples of 25mm and significantly assist onsite installation speed as well as the reduction of site waste. Custom cut lengths are available subject to request.
Internal Wall & Facade Profile Combinations
INTERNAL PROFILES
Note: Other profile combinations available dependent on application.
Please contact your ASKIN representative for availability of each profile.
Services
ASKIN can produce in-line services voids for special requirements.
Please contact your ASKIN representative for further information.
0.6mm (or 0.7mm) External Face Skin with 0.6mm Internal Face Skin
Standard Steel Specification
INTERNAL SKIN MATERIAL – 0.6 or 0.7mm Thick G300S AM100
high performance steel with pre-painted superior polyester finish
coat of 25 microns.
INTERNAL SKIN MATERIAL – 0.6mm Thick G300S Z275 pre-painted
Colorbond® Intramax® steel with superior polyester finish
coat of 25 microns. Colorbond® Intramax® steel is specifically
designed for temperature controlled environments.
Uniformly distributed ultimate limit state short term Wind load as derived from AS1170.2. Capacities derived from NATA approved structural testing in accordance with AS4040.2. Serviceability limit state deflection limited to span/150. Thermal deflection and required stress relief cuts should be considered for controlled environments by a suitably competent person. See ASKIN connection details for fire rated stress relief cuts.
Panel is assumed to be fixed from outside into a suitable structure inside. Fire rated walls and ceilings are non-load carrying and no permanent loads should be applied. Fixings, number and type should be considered by a suitably competent person. For FM approval requirements, please refer to specific test certificates available for download on our website. Loadings noted within span tables do not include the self-weight of the panel. Self weight will need to be applied when panel is used in a horizontal application (i.e. a roof or a ceiling).